girgit.org

Organic Chemistry: Some Basic Principles and Techniques

How do you get a pure compound? Methods of purification

The big ideaEvery purification method uses one difference between the compound and its impurities (in sublimation, solubility, boiling point or how strongly it sticks to a surface), and a sharp melting or boiling point tells you when you have succeeded.

In simple words

A compound fresh from a plant or a flask is never clean. To clean it you find one way in which it is different from the dirt. Maybe it turns to vapour sooner, dissolves better in hot liquid, or runs faster along a strip of paper. Use that difference to pull the two apart. A clean solid melts all at once at one temperature; a dirty one goes soft slowly.

The common methods are sublimation, crystallisation, distillation, differential extraction and chromatography. Purity is checked by the melting or boiling point: most pure compounds have sharp ones. Modern checks use chromatography and spectroscopy.

Sublimation

Some solids turn straight into vapour on heating, without melting. Sublimation uses this to separate a sublimable compound (camphor, naphthalene, iodine) from impurities that do not sublime: the vapour is cooled on a cold surface and the pure solid collects there.

Crystallisation

The most common way to purify an organic solid. Crystallisation uses the difference in solubility between the compound and its impurities in a suitable solvent.

  1. Choose a solvent in which the compound is barely soluble cold but quite soluble hot.
  2. Dissolve the impure solid in the hot solvent and concentrate to a nearly saturated solution.
  3. Cool it: the pure compound crystallises out. Filter it off. The liquid left, the mother liquor, holds the impurities and a little of the compound.

If the compound is very soluble in one solvent and barely soluble in another, a mixture of the two can work. Coloured impurities are removed by activated charcoal, which adsorbs them. If the impurities have similar solubility, repeated crystallisation is needed.

Distillation, four ways

Distillation separates a volatile liquid from non-volatile impurities, or liquids whose boiling points differ enough. The liquid is boiled, the vapour cooled in a condenser, and the liquid collected in a receiver.

MethodUse it whenExample
Simple distillationboiling points are far apartchloroform (334 K) from aniline (457 K)
Fractional distillationboiling points are closeseparating crude oil into fractions
Distillation under reduced pressurethe liquid boils very high or decomposes at or below its boiling pointglycerol from spent lye in the soap industry
Steam distillationthe compound is steam volatile and does not mix with wateraniline from an aniline–water mixture
  • Fractional distillation. The vapour passes up a fractionating column before the condenser. Its many surfaces let rising vapour meet falling liquid: the higher-boiling part condenses and runs back, the lower-boiling part re-vaporises and climbs, so the vapour at the top is nearly pure low-boiling liquid. Each condense-and-re-vaporise step is one theoretical plate; industrial columns have hundreds.
  • Reduced pressure. A liquid boils when its vapour pressure equals the outside pressure. Lower the outside pressure with a water pump or vacuum pump, and it boils at a lower temperature, before it can decompose.
  • Steam distillation. Steam is blown through the heated mixture. The mixture boils when \( p_1 + p_2 = p \), where \( p_1 \) is the vapour pressure of the organic liquid, \( p_2 \) that of water and \( p \) the atmospheric pressure. So the mixture boils below 373 K, below the boiling points of both liquids. The distillate is separated from water in a separating funnel.

Try it: add plates to a fractionating column and watch the top vapour get purer.

Try it: heat aniline with water and watch the two vapour pressures add up.

Not in the current textbook, but NEET has asked it: o-nitrophenol and p-nitrophenol are separated by steam distillation. In o-nitrophenol the –OH and –NO2 groups are next to each other and hold each other by an intramolecular hydrogen bond, so it is steam volatile. p-Nitrophenol forms hydrogen bonds between molecules and stays behind.

Differential extraction

To pull an organic compound out of water, shake the water with an organic solvent that does not mix with water and in which the compound dissolves better. Two layers form in a separating funnel; drain off the organic layer and remove the solvent by distillation or evaporation. If the compound is only a little soluble in the organic solvent, continuous extraction is used, with the same solvent passed through again and again.

Chromatography

Chromatography (Greek chroma, colour: it was first used on plant pigments) separates mixtures, purifies compounds and tests purity. The mixture is placed on a stationary phase (a solid or a liquid), and a mobile phase (a solvent, solvent mixture or gas) moves slowly over it. Components that cling more travel less, and they separate.

(a) Adsorption chromatography: compounds are adsorbed to different extents on an adsorbent such as silica gel or alumina.

  • Column chromatography: the adsorbent is packed in a glass tube with a stopcock. The mixture goes on top and an eluant (solvent) runs down. The most strongly adsorbed component stays near the top; others move further down and come out separately.
  • Thin layer chromatography (TLC): a layer of adsorbent about 0.2 mm thick on a glass plate, the chromaplate. The mixture is spotted about 2 cm from the bottom and the plate stands in eluant in a closed jar. As the eluant climbs, components move up different distances.
\[ R_f = \frac{\text{distance moved by the substance from the base line } (x)}{\text{distance moved by the solvent from the base line } (y)} \]

The retardation factor, \(R_f\), is always less than 1; a strongly adsorbed compound has a small \(R_f\). Coloured spots are seen directly. Colourless spots that fluoresce show up under UV light; others appear as brown spots in a jar with iodine crystals, or with a spray reagent, such as ninhydrin for amino acids.

Try it: develop a plate of spinach pigments and measure Rf as the solvent climbs.

(b) Partition chromatography: components are continuously shared out (partitioned) between the stationary and mobile phases. In paper chromatography, water trapped in special chromatography paper is the stationary phase and the solvent rising by capillary action is the mobile phase. The developed strip is a chromatogram.

Don't mix these up

  • Column chromatography and TLC are adsorption methods; paper chromatography is partition.
  • In paper chromatography the stationary phase is the water held in the paper, not the paper itself.
  • Steam distillation needs a compound that is volatile in steam and immiscible with water.

Words to know

Mother liquor
The solution left after crystals are filtered off.
Theoretical plate
One condensation and re-vaporisation step in a fractionating column.
Steam volatile
Able to distil over with steam below its own boiling point.
Stationary / mobile phase
The part that stays put / the part that flows in chromatography.
Eluant
The solvent that carries the mixture through a column or up a plate.
Rf value
Distance moved by a spot divided by distance moved by the solvent.

Why does steam distillation work below 373 K?

  1. Steam heats the compound above its boiling point
  2. The vapour pressures of water and the compound add up to atmospheric pressure sooner
  3. The compound dissolves in water and lowers its boiling point

On a TLC plate the solvent travels 10 cm and a spot 4 cm. Its Rf is

  1. 2.5
  2. 0.4
  3. 4 cm

Coloured impurities in crystallisation are removed using

  1. activated charcoal
  2. iodine crystals
  3. silica gel